    132kv Prefabricated Distribution Transformer Substation Explosion Proof

    Ask Lasest Price
    Brand Name : Tianan Electric
    Model Number : CZBT1-132
    Certification : IEC
    Price : Pending
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 10000 units/year
    Delivery Time : 45 days
    • Product Details
    • Company Profile

    132kv Prefabricated Distribution Transformer Substation Explosion Proof

    132 Kv Emergency Vehicle Mounted Transformer Substation / Prefabricated Substation​


    It is the first vehiclemounted movable substation in China. It has been sent to Iraq in Dec 2008. The product which has 132KV voltage class and 16000KVA capacity is completely researched & developed, designed and amnufactured by ourselves.

    >> Divided into HV part,main transformer,LV switchgear Room.
    >> HV Switch adopts ZF10-145(L) as main switch,barely mounted on a semi-trailer.
    >> LV side switchgear,control power,DC panel and control protection device.


    Service condition


    1 Ambient condition

    a. Altitude ≤ 1000m;

    b. Ambient temperature

    Range of temperature: -25℃~+40℃;

    c. Wind speed (outdoor) ≤ 35m/s;

    d. Relative humidity ≤ 90%(+25℃);

    e. Installation spot

    The place shall have no fire, explosion, chemical corrosion and exquisite vibration.

    2 Move condition of the substation

    a. Max. speed ≤ 30km/h,when road surface is flat;

    b. Max. speed ≤ 10km/h, when road surface is not flat.

    Note: If the above condition can’t satisfy requirements, customer can consult with manufacturer to resolve it.


    Table1

    No.ItemUnitParameter
    1System voltagekV132
    2Rated voltagekV145
    3Rated frequencyHz50
    4Rated currentA2000 ,1600
    5Rated 1min power frequency withstand voltagekV275
    6Rated lightning impulse withstand voltagekV650
    7Rated short time withstand currentKA25,31.5,40
    8Rated short time withstand times3
    9Rated peak withstand currentkA63,80,100

    Table 2 Rated technical parameter of circuit breaker

    No.ItemUnitParameter
    1System voltagekV132
    2Rated voltagekV145
    3Rated frequencyHz50
    4Rated currentA2000
    5Rated 1min power frequency withstand voltagekV275
    6Rated lightning impulse withstand voltagekV650
    7Rated short time withstand current / timeKA/s40/4
    8Rated peak withstand currentkA100
    9Rated short circuit breaking currentkA40
    10Rated short circuit making currentkA100
    11DC component%40
    12Rated operation sequenceO 0.3s CO 180s CO
    13Opening timems35±5
    14Closing timems105±15
    15Breaking timems≤60
    16Non-simultaneity between polesClosingms≤5
    Openingms≤3
    17Fracture no. of each pole1
    18Mechanical enduranceTimes≥6000
    19Full capacity continuous breaking timesTimes≥20
    20

    SF6 gas pressure

    (20℃)

    Rated valueMPa0.60
    Alarm valueMPa0.55
    Locking valueMPa0.50
    21

    SF6 gas moisture

    content(μl/l)

    Acceptance valuePPm≤150
    Operation allowable valuePPm≤300
    22SF6 yearly gas leakage rate%≤0.5
    23Total weight of each circuit breakerkg2000

    Table3 table4 Parameters of current transformer

    Rated primary current150,300,500,750,1000,1500,2000
    Rated secondary current5A

    Rated output capacity and accuracy level


    See table 4

    Current ratioRated output capacity VAMeasure accuracy levelProtection accuracy level

    150/5

    300/5

    500/5

    750/5

    1000/5

    1500/5

    2000/5

    20

    20

    30

    30,40

    40,50

    50

    50

    0.5

    0.5

    0.5

    0.5

    0.5

    0.5

    0.5

    5P20

    5P20

    5P20

    5P20

    5P20

    5P20

    5P20


    Note: (1) Straight-through type bushing current transformer is attached in the circuit breaker.


    Table5 Parameters of lightning arrester

    No.ItemUnitParameter
    1System voltagekV132
    2Rated voltagekV150
    3Rated frequencyHz50
    4Nominal discharge currentkA10
    5DC 1mA reference voltagekV≥245
    6Residual voltage under lightning impulse current (peak)kV≤435
    7Residual voltage under operation impulse current (peak)kV≤370
    22Residual voltage under steep wave impulse current (peak)kV≤490

    Table 6 Parameters of neutral point lightning arrester

    No.ItemUnitParameter
    1System voltagekV132
    2Rated voltagekV90
    3Rated frequencyHz50
    4Nominal discharge currentkA1.5
    5DC 1mA reference voltagekV≥140
    6Residual voltage under lightning impulse current (peak)kV≤260
    7Residual voltage under operation impulse current (peak)kV≤240
    8Residual voltage under steep wave impulse current (peak)kV/

    Table7 Technical parameters of switch equipment on LV side


    No.ItemUnitParameter
    1System voltagekV11.5
    2Rated voltagekV12
    3Rated frequencyHz50
    4Rated currentA2000,1600,1250,
    5Rated 1min power frequency withstand voltagekV42/48
    6Rated lightning impulse withstand voltagekV75/85
    7Rated short time withstand currentkA40,31.5,25
    8Rated short time withstand times4
    9Rated peak withstand currentkA100,80,63
    10Rated short circuit breaking currentkA40,31.5,25
    11Rated short circuit making currentkA100,80,63
    12Rated operation sequenceO 0.3s CO 180s CO
    13Mechanical enduranceTimes≥10000

    132kv Prefabricated Distribution Transformer Substation Explosion Proof

    Quality 132kv Prefabricated Distribution Transformer Substation Explosion Proof for sale