    Brand Name : Tianan Electric
    Model Number : HXGN26-12F
    Certification : ISO9001:2000, VDE, CCC, TUV
    Price : Pending
    Payment Terms : T/T, L/C, D/A, D/P, Western Union, MoneyGram
    Supply Ability : 2000sets per year
    Delivery Time : 45work days
    • Product Details
    • Company Profile

    Sf6 Rmu Mv Gis Ring Main Units And Compact Switchgear Systems Ac Metal - Clad


    Sf6 Rmu Mv Gis Ring Main Units And Compact Switchgear Systems Ac Metal - Clad


    AC Metal - clad SF6 RMU MV GIS Ring Main Units and Compact Switchgear

    Overview


    HXGN26-12(F) AC Metal-clad SF6 RMU Switchgear (hereinafter referred to as “RMU”), is designed and researched by our company through absorbing and digesting abroad advanced technology and combining power supply requirements of state.


    Features

    a. Main switch is FN26-12 SF6 load switch.

    b. Three phases are longitudinal arrangement.

    c. Two mechanism: manual drive, manual and motor drive.

    d. Enclosure: complete aluminum zinc coated steel plate.

    e. Reliable five-protection and interlock system.

    f. Easy wiring connection of control circuit between cubicles.


    Service condition
    a. Altitude≤1000m
    b. Ambient air temperature: Maximum +40ºC Minimum -35ºC
    c. Relative humidity: Diary average value shall be not more than 95%; monthly average value shall be
    not more than 90%.
    d. Ambient air should be with no corrosion, no apparent pollution with combustible gas and etc.
    e. Earthquake prevent function: process ground horizontal acceleration0.2g and vertical
    acceleration0.1g at the same time, adopt resonance,sine,whip wave test, safety factor should be more
    than 1.67

    Parameters

    NameUnitParameters
    Rated VoltagekV12
    Rated FrequencyHz50
    Rated Main Busbar CurrentA630
    Main Circuit, Earthing Circuit Rated Short-time Withstand CurrentkA/s25/2
    Main Circuit, Earthing Circuit Rated Peak Withstand CurrentkA63
    Main Circuit ,Earthing Circuit Rated Short-circuit Making CurrentkA63
    Full Capacity Breaking Times of Load SwitchTimes100
    Fuse Breaking CurrentkA31.5 40
    Service LifeTimes10000
    1min Power frequency withstand Voltage (r.m.s) Between Phases, to Earth/ Isolation DistancekA42/48
    Lightning Impulse Withstand Voltage (Peak) Between Phases, to Earthing/ Isolation DistancekV75/85
    Secondary Circuit 1min Power Frequency Withstand VoltagekV2