    Draw Out Low Voltage Switchgear , Under 4000a Electrical Distribution Panel

    Ask Lasest Price
    Brand Name : TIANAN Electric
    Model Number : GCS
    Certification : IEC61439, ISO9001,Test Report, CCC
    Price : Pending
    Payment Terms : L/C, T/T, D/A, D/P, Western Union, MoneyGram
    Supply Ability : 2000 sets Per year
    Delivery Time : 45 work days
    • Product Details
    • Company Profile

    Draw Out Low Voltage Switchgear , Under 4000a Electrical Distribution Panel

    Low Voltage Switchboard Draw - Out Switchgear Electric Distribution Panel


    Overview

    GCS low voltage draw-out switchgear (hereinafter referred to as the device) is a low voltage draw-out switchgear which is designed and developed jointly by the Ministry of Power Industry and the Ministry of Machine Building together with Design Team in accordance with the requirements of competent industry department, power consumers and design unit, accords with national situation of China, has high technical index and can adapt to the development needs of power market and compete with current imported product.

    Working condition

    1. The ambient air temperature shall not be higher than ±40℃ and not be lower than -5℃,and the average temperature within 24h shall not be higher than +35℃. If the temperature exceeds the above value, the device shall run with reduced capacity.

    2. When the air is clean, the relative humidity shall not exceed 50% at +40℃, and it may be higher at lower temperature, for example, 90% at +20℃. Then impact of condensation resulting from temperature variation should be considered.

    3. The inclination of equipment shall not exceed 5° at installation. The height above sea level in the place of use may not exceed 2,000m.

    4. The medium shall be free from explosive hazard and not contain the gas and conducting dust which may corrode metals and destroy the insulation.

    5. The user's special requirements may be solved through consultation with the company.


    Parameters

    Rated voltage of main circuit( V)400, 690
    Rated insulation voltage( V)690, 1000
    Rated frequency( Hz)50
    Rated insulation voltage( V)660( 1000)
    Rated current ( A)Horizontal busbar< =4000
    Vertical busbar1000
    Rated short time withstand current of busbar( kA/1s)80
    Rated peak withstand current of busbar( kA/0.1s)176
    Power frequency testing voltage (V/1min)Main circuit2500
    Auxiliary circuit1760
    Busbar3-phase and 4-wireA. B. C. PEN
    3-phase and 5-wireA. B. C. PE. N
    Protection degreeIP3L0. IP4L0
    Dimensions2200x (600 800 1000)x600(800 1000)