Sign In | Join Free | My himfr.com
Home > High Voltage Switchgear >

SF6 GIS , Gas Insulated Switchgear Indoor Metal-Enclosed Cabinet With 38KV

    Buy cheap SF6 GIS , Gas Insulated Switchgear Indoor Metal-Enclosed Cabinet With 38KV from wholesalers
     
    Buy cheap SF6 GIS , Gas Insulated Switchgear Indoor Metal-Enclosed Cabinet With 38KV from wholesalers
    • Buy cheap SF6 GIS , Gas Insulated Switchgear Indoor Metal-Enclosed Cabinet With 38KV from wholesalers
    • Buy cheap SF6 GIS , Gas Insulated Switchgear Indoor Metal-Enclosed Cabinet With 38KV from wholesalers
    • Buy cheap SF6 GIS , Gas Insulated Switchgear Indoor Metal-Enclosed Cabinet With 38KV from wholesalers

    SF6 GIS , Gas Insulated Switchgear Indoor Metal-Enclosed Cabinet With 38KV

    Ask Lasest Price
    Brand Name : Tianan Electric
    Model Number : DXG(XGN49)
    Certification : ISO9001:2000
    Price : Pending
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 5000 PCS/year
    Delivery Time : 45 work days
    • Product Details
    • Company Profile

    SF6 GIS , Gas Insulated Switchgear Indoor Metal-Enclosed Cabinet With 38KV

    SF6 Gas Insulated Switchgear Indoor Gas Insulatlon Metal Clad Switchgear


    General:

    XGN49 Series lndoor Gas lnsulatlon MetaI-clad Switchgear(hereinafter called C-GlS)is a high quality product which the China power industry federation sole recommends technology from Korea Rijin electrical equipment industry corporation and it meets Chinese standards of GB/T11022-1999 and GB3906-2006C-GlS.
    Product feature:
    The DXG-40.5(Z) GIS is suitable for power plant, substation, combined substation and electric power system, which is three phase indoor AC single busbar and sectioning single busbar with 50Hz, 35kV rated voltage, used to control, accept and distribute electric power.
    Service ambient condition:
    Air temperature: Max: +40, Min: -25 (average is not more than 35 in 24 hours)
    Altitude above sea level: <= 3000m
    Air humidity: The average relative humidity measured in 24 hours is not more than 95%, the average relative humidity per month is not more than 90%, average water vapor pressure measured in 24 hours is not more than 2.2kPa, average water vapor pressure per month is not more than 1.8 kPa.
    Without frequent heavy vibration
    The range of induction electromagnetic interference of secondary system is not more than 1.6kV
    Conditions excluded from above are in need of negotiating with the manufacturer.
    Ordering notice:
    Please provide these following materials while ordering:
    A. Scheme number of major loop and single wire system diagram, pareto diagram;
    B. Layout wiring diagram of secondary loop, terminal pareto diagram;
    C. Type, specification, quantity of electric components inside the switchgear;
    D. If without any request for the material and specification of busbar from customers, they come up with manufacturer'requirement;
    E. If the switchgear is used in special environmental condition, it should be marked while ordering;
    F. If without any request, the switchgear colour is up to the manufacturer'standards;
    G. Stored energy, control, voltage of signal power supply of the auxiliary circuit;
    H. Usage of each side of GIS;
    I. Variety and quantity of spare parts and accessories needed.


    Parameters:


    NameUnitParameters
    Rated VoltagekV40.5
    Rated CurrentA1250
    Rated FrequencyHz50
    Rated Power Frequency Withstand Voltage (1min)Between Phases, Phase to EarthkV95
    To open gap118
    Rated Lightning Impulse Withstand VoltageBetween Phases, Phase to EarthkV185
    To open gap125
    Secondary Circuit Power Frequency Withstand Voltage (1min)V2000
    Rated Short-circuit Breaking CurrentkA25
    Rated Short-circuit Making CurrentkA63
    Rated Short-time Withstand CurrentkA25
    Rated Peak Withstand CurrentkA63
    Rated Short-circuit Durations4
    Enclosure Protection Class (Air Inflation Shell/LV Cubicle)IP67/IP4X
    Main Circuit Resistance Each PhaseμΩ≤250
    Rated Operating Pressure of SF6 Gas (Gage pressure for 20℃ )Mpa0.05
    Minimum Operating Pressure of SF6 Gas (Gage pressure for 20℃ )Mpa0.03
    SF6 Gas Annual Gas Leakage Rate≤1
    Auxiliary Circuit Rated Operating VoltageVDC110/220
    Enclosure Dimension (Width*Depth*Height)mm(600~1200)*1400*2500

    Quality SF6 GIS , Gas Insulated Switchgear Indoor Metal-Enclosed Cabinet With 38KV for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Ningbo Tianan (Group) Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)